Validity of the augmentation index and pulse pressure amplification as determined by the SphygmoCor XCEL device: a
Atsushi Nakagomi1, Toshihiro Shoji1, Sho Okada1
1Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan.
Abstract:
Augmentation index (AIx) and pulse pressure (PP) amplification can be determined by the SphygmoCor XCEL device in an operator-independent manner. This study aimed to examine its validity against invasive measurements. Simultaneous recordings of central aortic pressure waveforms were performed with oscillometric and high-fidelity invasive methods in 35 patients who underwent coronary arteriography. Brachial blood pressure was also recorded using the two methods. AIx for the aortic pressure waveform was defined as the ratio of augmentation pressure to PP. PP amplification was defined as the ratio of brachial PP to aortic PP. The differences between the invasive and oscillometric measurements were -7.7±12.7% for AIx and 0.17±0.14 for PP amplification (mean±s.d.). Strong correlations between the invasive and oscillometric measurements were found in both indices (AIx: r=0.75; PP amplification: r=0.80; both P<0.001). The Bland-Altman plot showed a proportional bias of PP amplification, but not of AIx (AIx: r=-0.21, P=0.23; PP amplification: r=-0.61; P<0.001). In conclusion, estimated AIx may be reliable considering the high correlation between the invasive and noninvasive values and the lack of proportional bias against invasive assessment. However, a substantial underestimation and a large scatter of estimated AIx were also observed. Further studies using the device to investigate associations with target organ damage or prognoses are needed to clarify its clinical validity.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: