User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in
Srinivasarao Koppala1, V Ranga Reddy1, Jaya Shree Anireddy1
1Centre for Chemical Sciences and Technology, Institute of Science and Technology, Jawaharlal Nehru Technological University Hyderabad, Kukatpally, Hyderabad 500085, Telangana, India.
Abstract:
The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene-divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.
More Related Videos
08:59An Intestine/Liver Microphysiological System for Drug Pharmacokinetic and Toxicological Assessment
Published on: December 3, 2020
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Data Validation
Key parameters for method validation include:
High-Performance Liquid Chromatography: Elution Process
Clinically Relevant Drug Product Specifications: Methods of Establishment
High-Performance Liquid Chromatography: Instrumentation
In Vitro Drug Release Testing: Overview, Development and Validation
Development of Analytical Methods