Applications of high-resolution recycling liquid chromatography: From small to large molecules
Fabrice Gritti1, Sebastien Besner1, Sylvain Cormier1
1Waters Corporation, 34 Mapple Street, Milford, MA 01757, USA.
Abstract:
A twin-column recycling separation process (TCRSP) is assembled and used to generate higher speed and/or higher resolution levels than those of the usual non-recycling process at the same back pressure. It enables the users to solve very challenging separation problems caused by too small selectivity factors and/or too low column efficiencies. The relative gain in speed-resolution performance increases with increasing the number of cycles in the TCRSP, decreasing the maximum allowable pressure imposed by the LC system, decreasing the column permeability, and with reducing the separation speed. TCRSP is then particularly attractive for conventional LC systems (5000psi maximum) and columns packed with sub-2μm to 3.5μm particles. The performance of the real TCRSP was compared to that of the ideal TCRSP for which the retention factor is strictly pressure-independent. A broad range of separation problems encountered in conventional non-recycling chromatography can be easily solved by using a TCRSP assembly based on two 15cm long columns. Under adsorption conditions, the TCRSP enables the full baseline separation of polycyclic aromatic hydrocarbon (PAH) isomers (benzo[a]anthracene and chrysene) on a 3.5μm XSelect-HSS T3 phase, the complete or improved resolution of racemic mixtures (4-phenylbutanol and bromacil) using the same 2.5μm cellulose-1 chiral stationary phase, and the full resolution of isotopic compounds (benzene/1,3,5-benzene-d3/benzene-d6) on a 2.7μm Cortecs-C18 phase. Under non-adsorption conditions or in size-exclusion chromatography (SEC), the fractionation of a polystyrene standard mixture (molecular weights of 35, 66, 130, 277, 552, 1210, and 2500kDa) was completed after only 8 cycles on a 1.7μm BEH 200Åphase. Similarly, a mixture of intact proteins with molecular weights of 16.7, 66.4, 150, 660, and 1320kDa was fully resolved on a 2.5μm BEH 450Åphase after only 6 cycles. Finally, TCRSP enables the complete separation of a few high-molecular-weight species (monoclonal antibody aggregates, small relative abundance of 1 for 250) from the intact monomeric monoclonal antibody (Vectibix).
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process