Background:
Capnography has many uses in the emergency department (ED) and critical care setting, most commonly cardiac arrest and procedural sedation.
Objective Of The Review:
This review evaluates several indications concerning capnography beyond cardiac arrest and procedural sedation in the ED, as well as limitations and specific waveforms.
Discussion:
Capnography includes the noninvasive measurement of CO2, providing information on ventilation, perfusion, and metabolism in intubated and spontaneously breathing patients. Since the 1990s, capnography has been utilized extensively for cardiac arrest and procedural sedation. Qualitative capnography includes a colorimetric device, changing color on the amount of CO2 present. Quantitative capnography provides a numeric value (end-tidal CO2), and capnography most commonly includes a waveform as a function of time. Conditions in which capnography is informative include cardiac arrest, procedural sedation, mechanically ventilated patients, and patients with metabolic acidemia. Patients with seizure, trauma, and respiratory conditions, such as pulmonary embolism and obstructive airway disease, can benefit from capnography, but further study is needed. Limitations include use of capnography in conditions with mixed pathophysiology, patients with low tidal volumes, and equipment malfunction. Capnography should be used in conjunction with clinical assessment.
Conclusions:
Capnography demonstrates benefit in cardiac arrest, procedural sedation, mechanically ventilated patients, and patients with metabolic acidemia. Further study is required in patients with seizure, trauma, and respiratory conditions. It should only be used in conjunction with other patient factors and clinical assessment.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Acute Respiratory Failure-III
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Acute Respiratory Failure-IV
Methods of Documentation V: CBE
In CBE, healthcare professionals establish predefined standards of practice that define what constitutes...