Related Experiment Video
Updated: Feb 21, 2026

Exploring the Effects of Atmospheric Forcings on Evaporation: Experimental Integration of the Atmospheric Boundary Layer and Shallow Subsurface
Published on: June 8, 2015
Development of a modular vapor intrusion model with variably saturated and non-isothermal vadose zone
Dawit N Bekele1,2, Ravi Naidu3,4, Sreenivasulu Chadalavada4
1Global Centre for Environmental Remediation, ATC Building, University of Newcastle, University Dr, Callaghan, NSW, 2308, Australia. Dawit.Bekele@newcastle.edu.au.
Abstract:
Human health risk assessment at hydrocarbon-contaminated sites requires a critical evaluation of the exposure pathways of volatile organic compounds including assessments of vapor exposure in indoor air. Although there are a number of vapor intrusion models (VIM) currently available, they rarely reproduce actual properties of soils in the vadose zone. At best, users of such models assume averaged parameters for the vadose zone based on information generated elsewhere. The objective of this study was to develop a one-dimensional steady-state VIM, indoorCARE™ model, that considers vertical spatial variations of the degree of saturation (or effective air-filled porosity) and temperature of the vadose zone. The indoorCARE™ model was developed using a quasi-analytical equation that (1) solves the coupled equations governing soil-water movement driven by pressure head and a soil heat transport module describing conduction of heat and (2) provides a VIM that accommodates various types of conceptual site model (CSM) scenarios. The indoorCARE™ model is applicable to both chlorinated hydrocarbon and petroleum hydrocarbon (PHC) contaminated sites. The model incorporates biodegradations of PHCs at a range of CSM scenarios. The results demonstrate that predictions of indoor vapor concentrations made with the indoorCARE™ model are close to those of the J&E and BioVapor models under homogeneous vadose zone conditions. The newly developed model under heterogeneous vadose zone conditions demonstrated improved predictions of indoor vapor concentrations. The research study presented a more accurate and more realistic way to evaluate potential human health risks associated with the soil-vapor-to-indoor-air pathways.
Related Concept Videos
Vapor Pressure of Fluid
When a liquid is placed in a closed container with a small air space, and the space is evacuated, vapor molecules will...
Phase Transitions: Vaporization and Condensation
Vapor Pressure Lowering
Vapor Pressure
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Compartment Models: Single-Compartment Model