Patients With Brugada Syndrome and Implanted Cardioverter-Defibrillators: Long-Term Follow-Up
Jaime Hernandez-Ojeda1, Elena Arbelo1, Roger Borras1
1Arrhythmia Section, Cardiology Department, Hospital Clínic, Universitat de Barcelona, Barcelona, Spain; IDIBAPS, Institut d'Investigació August Pi i Sunyer (IDIBAPS), Barcelona, Spain.
Background:
Implantable cardioverter-defibrillator (ICD) indications for primary prevention in Brugada syndrome (BrS) are still debated.
Objectives:
The authors investigated the long-term outcome after ICD implantation in a large cohort of BrS patients.
Methods:
Of a total of 370 patients with BrS in follow-up (age 43 ± 14 years; 74% male), 104 patients (28.1%) were treated with ICDs. The authors analyzed the long-term incidence of shocks and complications.
Results:
An ICD was implanted for secondary prevention in 10 patients (9.6%) and for primary prevention in 94 patients (90.4%). After a follow-up of 9.3 ± 5.1 years, 21 patients (20.2%) experienced a total of 81 appropriate shocks (incidence rate 2.2 per 100 person-years). The rate of appropriate shocks was higher in secondary prevention patients (p < 0.01). However, 4 of the 45 asymptomatic patients (8.9%) experienced appropriate ICD therapy, all with a spontaneous type 1 electrocardiogram and inducible ventricular arrhythmias. In the multivariable analysis, type 1 electrocardiogram with syncope (hazard ratio: 4.96; 95% confidence interval: 1.87 to 13.14; p < 0.01) and secondary prevention indication (hazard ratio: 6.85; 95% confidence interval: 2.29 to 20.50; p < 0.01) were significant predictors of appropriate therapy. Nine patients (8.7%) experienced 37 inappropriate shocks (incidence rate 0.9 per 100 person-years). Twenty-one patients (20.2%) had other ICD-related complications (incidence rate 1.4 per 100 person-years). Three patients (2.9%) died (1 electrical storm and 2 noncardiovascular deaths).
Conclusions:
ICD therapy is an effective therapy in high-risk patients with BrS. However, it is also associated with a significant risk of device-related complications. Special care during ICD implantation, adequate device programming, and regular follow-up may allow reducing the number of adverse events.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Cardiopulmonary Resuscitation III: AED Use
Cardiomyopathy V: Interprofessional Care
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias