Related Experiment Video
Updated: Feb 21, 2026

Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
Hand Grip Strength and Gender: Allometric Normalization in Older Adults and Implications for the NIOSH Lifting
Trish Gail Sevene1, Joseph Berning2, Chad Harris3
1Kinesiology Department, California State University Monterey Bay, Seaside, CA, USA.
Background:
Many countries are experiencing an aging workforce with women workers making up a growing proportion. Workplaces often require employees to complete lifting tasks that require the ability of the hand to grasp an implement (coupling). The National Institute for Occupational Safety and Health (NIOSH) has developed an equation for manual lifting tasks hoping to minimize the potential for a workplace back-injury related to a lifting task. The NIOSH lifting equation relies upon stress variables including a coupling factor. However, little is known regarding grip strength as related to the NIOSH lifting equation coupling factor. The purpose of this study was to investigate differences in grip strength due to gender in older adults.
Methods:
The participant's (68-88 years) maximal grip (MG) strength measures were collected for each hand with a hand grip dynamometer (kg). MG scores were converted to Newtons (N), normalized to body mass, and allometrically scaled. Measures of MG were than compared between genders with an independent t-test.
Results:
The hand grip measures of MG (kg) [male: 30.3 ± 5.6, female: 10.6 ± 3.3], MG (kg) / body mass (kg) [male: 0.35 ± 0.06, female: 0.16 ± 0.04], MG (N) / (body mass (kg))0.67 [male: 15.1 ± 2.5, female: 6.2 ± 1.7], and MG (N) / (body height (m))1.84 [male: 103.6 ± 18.6, female: 42.6 ± 10.6] were all significantly lower (p < 0.0001) for women than men. Regardless of how grip strength was reported, there is a strong difference in grip strength between genders in this sample. The NIOSH lifting equation does not account for varying grip strength due to aging and gender differences.
Conclusions:
It is recommended that grip strength variability be accounted for in the coupling factor of the NIOSH lifting equation.
Related Concept Videos
Two-Way ANOVA
The two-way ANOVA analysis initially begins by stating the null hypothesis that there is an interaction effect between the two factors of a dataset. This effect can be visualized using line segments formed by joining the...
Changes in the Appendicular Skeleton with Age
Initially, the limb buds consist of a core of mesenchyme covered by a layer of ectoderm. The ectoderm at the end of the limb bud thickens to form a narrow crest called the apical ectodermal ridge. This ridge stimulates the underlying...

