Related Experiment Video
Updated: Feb 20, 2026

Laparoscopic Anterior Right Hepatectomy: A Single-Center Experience
Published on: December 4, 2023
Robotic laparoendoscopic single-site benign gynecologic surgery: a single-center experience
J Jayakumaran1, K Wiercinski2, C Buffington2
1Department of Obstetrics and Gynecology, University of Central Florida College of Medicine, 70 West Gore Street, Orlando, FL, 34743, USA. drjphari@gmail.com.
The da Vinci Xi system is feasible and safe for robotic single-site gynecologic surgery in select patients. Early cases showed significant decreases in surgical times and blood loss, indicating a learning curve benefit.
Area of Science:
- Minimally Invasive Surgery
- Robotic Surgery
- Gynecologic Surgery
Background:
- The da Vinci Xi surgical system offers upgrades for minimally invasive procedures.
- Robotic surgery is increasingly used in gynecology.
Purpose of the Study:
- To evaluate the preliminary feasibility and safety of robotic laparoendoscopic single-site (R-LESS) gynecologic surgery using the da Vinci Xi system.
- To assess surgical outcomes and identify factors influencing operative time and blood loss.
Main Methods:
- Retrospective review of 35 female patients undergoing R-LESS gynecologic surgery for benign indications between June 2016 and January 2017.
- Analysis of operative times, complication rates, and blood loss.
- Comparison of early (first 12) versus later (subsequent 12) R-LESS hysterectomy cases.
- Logistic regression analysis to assess the association between BMI and surgical parameters.
Main Results:
- Median console time for hysterectomy was 41 minutes; median vaginal cuff closure time was 18 minutes.
- Conversion to multiport surgery occurred in 5.7% of cases; one major intraoperative complication (2.9%) was recorded.
- No patients required blood transfusion.
- A statistically significant decrease in surgical times and estimated blood loss was observed when comparing early and later R-LESS hysterectomy cases, suggesting a learning curve effect.
- No significant association was found between BMI and port entry time, console time, cuff closure time, operative time, or estimated blood loss.
Conclusions:
- The da Vinci Xi system demonstrates feasibility and safety for R-LESS gynecologic surgery in select patients.
- A learning curve effect was observed, with improved surgical efficiency in later cases.
- Further multi-center studies are warranted to fully establish the role of the da Vinci Xi system in single-site gynecologic procedures.
More Related Videos
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
05:16Laparoscopy-endoscopy Cooperative Surgery for the Treatment of Gastric Gastrointestinal Stromal Tumors
Published on: February 19, 2022