Related Experiment Video
Updated: Aug 12, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Novel method for intraoperative assessment of cerebral autoregulation by paced breathing
N H Sperna Weiland1,2, J Hermanides1, M W Hollmann1
1Department of Anaesthesiology.
Background:
Cerebral autoregulation (CA) is the mechanism that maintains constancy of cerebral blood flow (CBF) despite variations in blood pressure (BP). Patients with attenuated CA have been shown to have an increased incidence of peri-operative stroke. Studies of CA in anaesthetized subjects are rare, because a simple and non-invasive method to quantify the integrity of CA is not available. In this study, we set out to improve non-invasive quantification of CA during surgery. For this purpose, we introduce a novel method to amplify spontaneous BP fluctuations during surgery by imposing mechanical positive pressure ventilation at three different frequencies and quantify CA from the resulting BP oscillations.
Methods:
Fourteen patients undergoing sevoflurane anaesthesia were included in the study. Continuous non-invasive BP and transcranial Doppler-derived CBF velocity (CBF V ) were obtained before surgery during 3 min of paced breathing at 6, 10, and 15 bpm and during surgery from mechanical positive pressure ventilation at identical frequencies. Data were analysed using frequency domain analysis to obtain CBF V -to-BP phase lead as a continuous measure of CA efficacy. Group averages were calculated. Values are means ( sd ), and P <0.05 was used to indicate statistical significance.
Results:
Preoperative vs intraoperative CBF V -to-BP phase lead was 43 (9) vs 45 (8)°, 25 (8) vs 24 (10)°, and 4 (6) vs -2 (12)° during 6, 10, and 15 bpm, respectively (all P =NS).
Conclusions:
During surgery, cerebral autoregulation indices were similar to values determined before surgery. This indicates that CA can be quantified reliably and non-invasively using this novel method and confirms earlier evidence that CA is unaffected by sevoflurane anaesthesia.
Clinical Trial Registration:
NCT03071432.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...