Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

8.7K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.7K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

1.9K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
1.9K
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

2.7K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.7K
MALDI-TOF Mass Spectrometry01:19

MALDI-TOF Mass Spectrometry

7.1K
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
7.1K
Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

1.2K
Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Atomic Imaging Reveals Low-Hysteresis Oxygen Redox in Transition Metal Vacancy-Engineered Sodium Ion Cathodes.

ACS applied materials & interfaces·2026
Same author

Nanoporous PVDF-HFP/PMIA Membrane with Heat-Resistance towards the Gel Polymer Electrolyte of Lithium Metal Batteries.

ACS applied materials & interfaces·2026
Same author

Multifunctional C/Co Aerogels with Integrated Robustness, Hydrophobicity, Flame Retardancy, and Microwave Absorption Performance.

ACS applied materials & interfaces·2026
Same author

Magnetic Metal-Organic Framework (MOF)-Mediated Precision Capture of Mitochondria Reveals Subcellular Metabolic and Lipid Remodeling of Crabtree Effect in Yeast.

Analytical chemistry·2026
Same author

Salvianolic Acid B Inhibits Ferroptosis Through ACSL4 Pathway Regulation in sepsis-associated encephalopathy Mice.

Molecular neurobiology·2026
Same author

Machine Learning-Based Model for Predicting Acute Kidney Injury in Patients Hospitalized with Heart Failure: Development and Validation Study.

CJC open·2026
Same journal

Smartphone-assisted fluorescence and colorimetric dual-mode sensor for visual quantitative detection of nitrite and nitrate in real samples.

Analytica chimica acta·2026
Same journal

Folding integrated all-paper photoelectrochemical immunoassay using annealed ZnO for point-of-care detection of ferritin.

Analytica chimica acta·2026
Same journal

Dual-mode electrochemical-SERS detection of chloramphenicol based on dual-signal enhancement.

Analytica chimica acta·2026
Same journal

Multi-screening of beta-lactam antibiotics in milk based on Fe<sub>3</sub>O<sub>4</sub>@phage/bacteria system and aggregation induced emission luminogen.

Analytica chimica acta·2026
Same journal

A porous phosphate-rich β-cyclodextrin polymer for efficient and broad-spectrum enrichment of antibiotics.

Analytica chimica acta·2026
Same journal

Corrigendum to "LUMIN: A novel algorithm for automated mixture quantification using 1D <sup>1</sup>H NMR spectra" [Analytica Chimica Acta 1411 (2026) 345639].

Analytica chimica acta·2026
See all related articles

Related Experiment Video

Updated: Feb 20, 2026

A Strategy for Sensitive, Large Scale Quantitative Metabolomics
14:18

A Strategy for Sensitive, Large Scale Quantitative Metabolomics

Published on: May 27, 2014

21.8K

An alignment algorithm for LC-MS-based metabolomics dataset assisted by MS/MS information.

Lili Li1, Weijie Ren2, Hongwei Kong3

  • 1CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China; University of Chinese Academy of Sciences, Beijing 100049, China.

Analytica Chimica Acta
|October 15, 2017
PubMed
Summary
This summary is machine-generated.

This study introduces a new MS/MS-based method for aligning liquid chromatography-mass spectrometry (LC-MS) metabolomics data. The approach effectively corrects retention time drift, improving data reliability for metabolomics studies.

Keywords:
Liquid chromatography-mass spectrometryMetabolic profilingMetabolomicsPeak alignmentTandem mass spectrometry

More Related Videos

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

13.4K
Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
11:00

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS

Published on: May 20, 2013

23.5K

Related Experiment Videos

Last Updated: Feb 20, 2026

A Strategy for Sensitive, Large Scale Quantitative Metabolomics
14:18

A Strategy for Sensitive, Large Scale Quantitative Metabolomics

Published on: May 27, 2014

21.8K
Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
07:34

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS

Published on: March 14, 2013

13.4K
Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
11:00

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS

Published on: May 20, 2013

23.5K

Area of Science:

  • Analytical Chemistry
  • Biochemistry
  • Metabolomics

Background:

  • Liquid chromatography-mass spectrometry (LC-MS) is a crucial analytical technique in metabolomics.
  • Accurate peak alignment of LC-MS data is essential for reliable metabolomics studies.
  • Existing alignment methods can struggle with significant retention time drift in datasets.

Purpose of the Study:

  • To develop a robust MS/MS-based peak alignment method for LC-MS metabolomics data.
  • To address challenges posed by larger retention time drifts in metabolomics datasets.
  • To provide a reliable and simple alignment solution for LC-MS data.

Main Methods:

  • A novel strategy for screening endogenous reference variables using MS, MS/MS, and retention time.
  • Selection and confirmation of multiple robust endogenous reference variables across samples.
  • Correction of metabolite feature retention times using local linear regression with identified reference variables.
  • Final peak alignment based on corrected retention time, MS, and MS/MS data.

Main Results:

  • The developed MS/MS-based method demonstrated superior performance compared to two other alignment techniques.
  • The method effectively handles metabolomics data exhibiting substantial retention time drift.
  • The approach provides a simple, robust, and reliable solution for aligning LC-MS metabolomics datasets.

Conclusions:

  • The proposed peak alignment method is highly suitable for LC-MS metabolomics data, especially with significant retention time variations.
  • This technique enhances the reliability and accuracy of metabolomics data analysis.
  • The developed approach offers a valuable tool for researchers in the field of metabolomics.