Solid phase extraction based on porous magnetic graphene oxide/β-cyclodextrine composite coupled with high
Jingyi Zhang1, Donghao Liu1, Xiaoyan Meng1
1Department of Analytical Chemistry, China Pharmaceutical University, 24 Tongjia Lane, Nanjing 210009, China.
Abstract:
In this study, a novel solid phase extraction based on porous magnetic graphene oxide-cyclodextrin polymers (MGO-CD) was developed with aromatic linker and used for the simultaneous extraction and preconcentration of trace antiepileptic drugs in plasma. The characteristics of MGO-CD were assessed by Fourier transform infrared spectroscopy (FT-IR), Brunauer-Emmett-Teller surface areas (BET), Transmission Electron Microscope (TEM), Scanning Electron Microscope (SEM), X-ray diffraction (XRD) and vibrating sample magnetometer (VSM). Magnetic cyclodextrin polymeric material exhibited a high specific surface area (187m2g-1), large pore volume (0.12cm3g-1), good saturated magnetization (37.68emug-1), and excellent dispersibility in aqueous solution. Various parameters influencing the extraction recovery of drugs were studied. The method exhibited good linearity in the range of 1-50μgmL-1, and the limit of quantitation of carbamazepine, phenytoin, diazepam was 11.89, 47.10 and 16.17ngmL-1, respectively. The recoveries of three antiepileptic drugs range from 78.49 to 100.93% with relative standard deviations less than 5.5%. These analytical results demonstrated that the proposed approach based on MGO-CD was applicable for analysis of antiepileptic drugs in plasma samples.
More Related Videos
07:51Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
