Related Experiment Video
Updated: Oct 14, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 17, 2014
Driveline Site Is Not a Predictor of Infection After Ventricular Assist Device Implantation
Billie-Jean Martin1, Jessica G Y Luc2, Michiko Maruyama3
1From the Division of Cardiothoracic Surgery, Stanford University, Stanford, California.
Abstract:
Driveline infections (DLIs) remain a major source of morbidity for patients requiring long-term ventricular assist device (VAD) support. We aimed to assess whether VAD driveline exit site (DLES) (abdomen versus chest wall) is associated with DLI. All adult patients who underwent insertion of a HeartWare HVAD or HeartMate II (HMII) between 2009 and 2016 were included. Driveline infection was defined as clinical evidence of DLI accompanied by a positive bacterial swab and need for antibiotics. Competing risks analysis was used to assess the association between patient characteristics and DLI. Ninety-two devices (59 HMII) were implanted in 85 patients (72 men; median age 57.4 years) for bridge to transplant or destination therapy. VAD DLES was chest in 28 (30.4%) devices. Median time on VAD support was 347.5 days (IQR 145.5, 757.5), with 28 transplants and 29 deaths (27 on device). DLI occurred in 24 patients (25 devices) at a median of 140 days (IQR 67, 314) from implant. Staphylococcus aureus accounted for 15 infections (60%). Freedom from infection was 72.8% (95% confidence interval [CI] 53.1-78.0%) at 1 year and 41.9% (95% CI 21.1-61.5%) at 3 years. In competing risks regression, abdominal DLES was not predictive of DLI (hazard ratio, HR 1.65 [95% CI 0.63, 4.29]), but body mass index (BMI) >30 kg/m was (HR 2.72 [95% CI 1.25, 5.92]). In conclusion, risk of DLI is high among patients on long-term VAD support, and a nonabdominal DLES does not reduce this risk. The only predictor of DLI in this series was an elevated BMI.
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin create...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiac Catheterization IV: Nursing Management
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications