Related Experiment Video
Updated: Aug 1, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 10, 2014
FLUKA-BASED MONTE CARLO INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTIONS OF TELECOBALT BEAM
T Palani Selvam1, Arghya Chattaraj1, D Datta1
1Radiological Physics & Advisory Division, Health, Safety & Environment Group, Bhabha Atomic Research Centre, Mumbai 400094, India.
Abstract:
FLUKA-based Monte Carlo calculations of microdosimetric distributions in water phantom involving a walled spherical Tissue-Equivalent Proportional Counter filled with tissue-equivalent propane gas have been studied for an indigenously developed telecobalt machine. The simulated site size considered in the study was 2 μm. In the Monte Carlo calculations, field size was varied from 10 cm × 10 cm to 35 cm × 35 cm and the depth was varied as 5-20 cm. The study also includes calculation of microdosimetric distributions with a 30° wedge filter. The efficiency of the calculations was improved up to a factor of 26 by choosing appropriate cut off values for production and transport of electrons. The calculated microdosimetric distributions of telecobalt machine is distinctly different from that of a bare 60Co source which is attributed to the influence of scattered photons from the machine head and the water phantom.