How Does Level and Type of Experience Affect Measurement of Joint Range of Motion?
Russell R Russo1, Matthew B Burn1, Sabir K Ismaily2
1Department of Orthopedics & Sports Medicine, Houston Methodist Hospital, Houston, Texas.
Objectives:
Comparison of range of motion measurements by 3 types of investigators with different levels and types of training using three different measurement techniques. The study hypothesis was that the accuracy and precision of range of motion measurements would vary based on (1) the level and type of experience of the investigator and (2) the measurement technique used.
Design/Setting:
Descriptive laboratory study.
Participants:
Ten fresh frozen cadavers (20 upper and 20 lower extremities).
Interventions:
Shoulder, elbow, hip, and knee motion were measured using 3 different measurement techniques (digital photography, goniometry, and visual estimation) by 3 groups of investigators (attending orthopedic surgeons, physical therapists, and residents). Accuracy was defined by the difference from the reference standard (motion capture analysis), whereas precision was defined by the proportion of measurements within either 5° or 10° of the reference standard. Analysis of variance, t-tests, and chi-squared tests were used.
Results:
Statistically significant (p < 0.05) differences in accuracy were found for hip flexion, abduction, internal rotation, external rotation, and knee flexion. However, none of these differences met the authors' defined clinical significance (maximum difference 3°). Precision was significantly (p < 0.05) different for elbow extension, hip flexion, abduction, internal rotation, external rotation, and knee flexion.
Conclusion:
This study found that clinically accurate measurements of shoulder, elbow, hip, and knee motion are obtained regardless of technique used or the investigators' level and type of experience. Precision was equivalent for all shoulder motions, elbow flexion, and knee extension, but varied by as much as 7% to 28% between groups for all other motions.
More Related Videos
Related Concept Videos
Measurements of Strain
Functional Classification of Joints
The functional classification of joints is determined by the amount of mobility between the adjacent bones. Joints are functionally classified as a synarthrosis or immobile joint, an amphiarthrosis or slightly moveable joint, or as a diarthrosis, a freely moveable joint. Fibrous and cartilaginous joints can be functionally classified as either synarthroses or amphiarthroses, whereas all synovial joints are classified as diarthroses.
Synarthrosis
An...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Uncertainty in Measurement: Reading Instruments
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...