Breast Cancer Risk Associations with Digital Mammographic Density by Pixel Brightness Threshold and Mammographic
Tuong L Nguyen1, Yoon-Ho Choi1, Ye K Aung1
1From the Melbourne School of Population and Global Health, Centre for Epidemiology and Biostatistics, University of Melbourne, Level 3, 207 Bouverie St, Carlton, VIC 3053, Australia (T.L.N., Y.K.A., C.F.E., N.H.T., S.L., G.S.D., M.A.J., J.L.H.); Center for Health Promotion, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea (Y.H.C..); Department of Radiology, National Cancer Center, Goyang-si, South Korea (M.S.K.); Faculty of Health Sciences, University of Sydney, Lidcombe, NSW, Australia (P.C.B.); Department of Epidemiology School of Public Health and Institute of Health and Environment, Seoul National University, Seoul, Korea (J.S., J.L.H.); and Department of Family Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea (Y.M.S.).
Abstract:
Purpose To compare three mammographic density measures defined by different pixel intensity thresholds as predictors of breast cancer risk for two different digital mammographic systems. Materials and Methods The Korean Breast Cancer Study included 398 women with invasive breast cancer and 737 control participants matched for age at mammography (±1 year), examination date, mammographic system, and menopausal status. Mammographic density was measured by using the automated Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) software and the semiautomated Cumulus software at the conventional threshold (Cumulus) and at increasingly higher thresholds (Altocumulus and Cirrocumulus, respectively). Measures were Box-Cox-transformed and adjusted for age, body mass index, and menopausal status. Conditional logistic regression was used to estimate risk associations. For calculation of measures of predictive value, the change in odds per standard deviation (OPERA) and the area under the receiver operating characteristic curve (AUC) were used. Results For dense area, with use of the direct conversion system the OPERAs were 1.72 (95% confidence interval [CI]: 1.38, 2.15) for LIBRA, 1.58 (95% CI: 1.27, 1.97) for Cumulus, 2.04 (95% CI: 1.60, 2.59) for Altocumulus, and 3.48 (95% CI: 2.45, 4.47) for Cirrocumulus (P < .001). The corresponding AUCs were 0.70, 0.69, 0.76, and 0.89, respectively. With use of the indirect conversion system, the corresponding OPERAs were 1.50 (95% CI: 1.28, 1.76), 1.36 (95% CI: 1.16, 1.59), 1.40 (95% CI: 1.19, 1.64), and 1.47 (95% CI: 1.25, 1.73) (P < .001) and the AUCs were 0.64, 0.60, 0.61, and 0.63, respectively. Conclusion It is possible that mammographic density defined by higher pixel thresholds could capture more risk-predicting information with use of a direct conversion mammographic system; the mammographically bright, rather than white, regions are etiologically important. © RSNA, 2017.