PAPR reduction based on tone reservation scheme for DCO-OFDM indoor visible light communications

Optics Express
|October 19, 2017
PubMed

Related Concept Videos

Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by:
634
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
395
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
577
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
501
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
401
IR Frequency Region: X–H Stretching01:24

IR Frequency Region: X–H Stretching

In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of  2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
1.5K