Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

10.0K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Genetically engineered bacterial magnetosomes as optimized tracers for magnetic particle imaging.

Acta biomaterialia·2026
Same author

Deep learning for restoring MPI system matrices using simulated training data.

Physics in medicine and biology·2026
Same author

Continuous Coagulation Monitoring in Human Blood Samples via Magnetic Particle Spectroscopy.

International journal of nanomedicine·2026
Same author

The influence of muscle shapes on HDsEMG decomposition yield and accuracy.

Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology·2026
Same author

NMR relaxometry probes solvent-polarity-dependent molecular interactions in stimuli-responsive lyogels.

Physical chemistry chemical physics : PCCP·2025
Same author

Simulation of Diaphragmatic Motor Unit Action Potentials Throughout the Respiratory Cycle Using a Dynamic Breathing Model<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

Related Experiment Video

Updated: Feb 20, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

10.0K

Fast multiresolution data acquisition for magnetic particle imaging using adaptive feature detection.

Nadine Gdaniec1,2, Patryk Szwargulski1,2, Tobias Knopp1,2

  • 1Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, 22529, Hamburg, Germany.

Medical Physics
|October 19, 2017
PubMed
Summary
This summary is machine-generated.

This study introduces an adaptive multigradient imaging sequence for magnetic particle imaging (MPI). This method achieves high spatial and temporal resolution across a large field of view, crucial for human applications.

Keywords:
magnetic particle imagingmultigradientmultipatch

More Related Videos

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.9K
Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
07:42

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Published on: July 20, 2022

3.4K

Related Experiment Videos

Last Updated: Feb 20, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

10.0K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.9K
Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
07:42

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Published on: July 20, 2022

3.4K

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • Nanotechnology

Background:

  • Magnetic particle imaging (MPI) offers high temporal resolution for nanoparticle distribution.
  • Spatial resolution in MPI is limited by selection field gradient strength, affecting imaging volume.
  • Current multipatch approaches for extended fields-of-view degrade temporal resolution.

Purpose of the Study:

  • To develop an adaptive scanning procedure combining advantages of multiple gradient strengths in MPI.
  • To overcome the trade-off between spatial resolution, imaging volume, and temporal resolution in MPI.

Main Methods:

  • Implemented a scanning procedure starting with a low-resolution overview scan.
  • Utilized adaptively detected locations from the overview scan for subsequent high-resolution scans.
  • Combined data during image reconstruction to create a large field-of-view image.

Main Results:

  • Achieved a large field-of-view image with anisotropic spatial resolution.
  • Acquisition time was significantly reduced compared to fully sampled high-resolution imaging.
  • Demonstrated the ability to capture extended areas at high resolution.

Conclusions:

  • MPI is a flexible imaging modality for rapid, high-resolution small volume scanning.
  • Scaling MPI for human applications requires maintaining low acquisition times for large volumes.
  • The proposed adaptive multigradient imaging sequence successfully enhances both temporal and spatial resolution over a large field of view.