Comparative study of cylindrical and parallel-plate electrophoretic separations for the removal of ions and sub-23 nm
Tongzhu Yu1,2, Yixin Yang1,2, Jianguo Liu1,2,3
1Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, China.
Abstract:
Cylindrical and parallel-plate electrophoretic separations for the removal of ions and sub-23 nm particles were compared in this study. First, COMSOL Multiphysics® software was utilized to simulate the ion and particle trajectories inside both electrophoretic separations. The results show that ions and sub-23 nm particles are removed simultaneously and that all particles can pass through both electrophoretic separations smoothly at a trap voltage of 25 V. The experimental results show that ion losses become smaller with increasing ion flow rates, and ion losses of the cylindrical and parallel-plate electrophoretic separations range from 56.2 to 71.6% and from 43.8 to 59.6%, respectively, at ion flow rates ranging from 1-3 L/min. For the removal of ions and sub-23 nm particles, the collection efficiency of both electrophoretic separations can reach 100%, but the parallel-plate electrophoretic separation requires a lower trap voltage. The particle loss of the parallel-plate electrophoretic separation is under approximately 10%, which is lower than that of the cylindrical electrophoretic separation. In particular, for large particles (800-2500 nm), the particle losses inside the cylindrical electrophoretic separation are approximately two times higher than those inside the parallel-plate electrophoretic separation. The parallel-plate electrophoretic separation is beneficial for the removal of ions and sub-23 nm particles.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Ion-Exchange Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Capillary Electrophoresis: Instrumentation
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...