Dual-energy CT based proton range prediction in head and pelvic tumor patients
Patrick Wohlfahrt1, Christian Möhler2, Kristin Stützer1
1OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.
Background And Purpose:
To reduce range uncertainty in particle therapy, an accurate computation of stopping-power ratios (SPRs) based on computed tomography (CT) is crucial. Here, we assess range differences between the state-of-the-art CT-number-to-SPR conversion using a generic Hounsfield look-up table (HLUT) and a direct patient-specific SPR prediction (RhoSigma) based on dual-energy CT (DECT) in 100 proton treatment fields.
Material And Methods:
For 25 head-tumor and 25 prostate-cancer patients, the clinically applied treatment plan, optimized using a HLUT, was recalculated with RhoSigma as CT-number-to-SPR conversion. Depth-dose curves in beam direction were extracted for both dose distributions in a regular grid and range deviations were determined and correlated to SPR differences within the irradiated volume.
Results:
Absolute (relative) mean water-equivalent range shifts of 1.1mm (1.2%) and 4.1mm (1.7%) were observed in the head-tumor and prostate-cancer cohort, respectively. Due to the case dependency of a generic HLUT, range deviations within treatment fields strongly depend on the tissues traversed leading to a larger variation within one patient than between patients.
Conclusions:
The magnitude of patient-specific range deviations between HLUT and the more accurate DECT-based SPR prediction is clinically relevant. A clinical application of the latter seems feasible as demonstrated in this study using medically approved systems from CT acquisition to treatment planning.