Coordinated single-phase control scheme for voltage unbalance reduction in low voltage network

Deepak Pullaguram1, Sukumar Mishra2, Nilanjan Senroy2

  • 1Electrical Engineering Department, Indian Institute of Technology Delhi, New Delhi 10016, India deepak.pullaguram@gmail.com.

Summary

A new multi-agent system coordinates single-phase sources to reduce voltage unbalance in low voltage (LV) distribution systems. This approach ensures balanced voltages and fair power sharing across the network.

Related Concept Videos

Three-Phase Voltages01:30

Three-Phase Voltages

A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
624
The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.2K
The Y-to-Y Circuit01:19

The Y-to-Y Circuit

In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and...
777
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
703
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
949
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
401