Nerve Ultrasound Protocol to Detect Dysimmune Neuropathies
Published on: October 7, 2021
Sonographic evaluation of the vagus nerves: Protocol, reference values, and side-to-side differences.
Johann Otto Pelz1, Elena Belau1, Philipp Henn1
1Department of Neurology, Leipzig University Hospital, Liebigstrasse 20, 04103 Leipzig, Germany.
This study establishes new sonographic reference values for vagus nerves (VNs) in healthy adults. The right vagus nerve is larger, and measurements show good agreement across sonographers and ultrasound systems.
Area of Science:
- Neurology
- Medical Imaging
- Anatomy
Background:
- Sonographic reference values for vagus nerves (VNs) exhibit significant variability.
- Establishing reliable reference values is crucial for accurate clinical assessment.
Purpose of the Study:
- To generate robust sonographic reference values for the vagus nerves in a large cohort.
- To evaluate the agreement of vagus nerve measurements across different sonographers and ultrasound systems.
Main Methods:
- Ultrasound examinations of vagus nerves (VNs) were performed on 60 healthy subjects.
- Cross-sectional areas (CSAs) of VNs were measured at proximal and distal levels.
- Two sonographers and two ultrasound systems were utilized to assess interrater and system agreement.
Main Results:
- Mean right VN CSA was significantly larger than the left at both proximal and distal measurement levels.
- Vagus nerve (VN) CSA demonstrated a decrease with increasing age.
- Good intrarater, interrater, and across-ultrasound system agreement was observed.
Conclusions:
- The study provides side- and age-specific sonographic reference values for the vagus nerve (VN).
- These reference values may enhance the accuracy of future diagnostic and research applications involving the vagus nerve.
More Related Videos
Related Concept Videos
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Imaging Studies II: Ultrasonography
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.