Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Instrument to detect syncope and the onset of shock
Daniel R McAdams1, Noah J Kolodziejski1, Christopher J Stapels1
1Radiation Monitoring Devices, Inc. 44 Hunt St., Watertown, MA 02472.
Abstract:
Currently the diagnosis of hemorrhagic shock is essentially clinical, relying on the expertise of nurses and doctors. One of the first measurable physiological changes that marks the onset of hemorrhagic shock is a decrease in capillary blood flow. Diffuse correlation spectroscopy (DCS) quantifies this decrease. DCS collects and analyzes multiply scattered, coherent, near infrared light to assess relative blood flow. This work presents a preliminary study using a DCS instrument with human subjects undergoing a lower body negative pressure (LBNP) protocol. This work builds on previous successful DCS instrumentation development and we believe it represents progress toward understanding how DCS can be used in a clinical setting.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Cardiopulmonary Resuscitation III: AED Use