Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.7K
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

1.2K
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
1.2K
Sites for measuring blood pressure01:21

Sites for measuring blood pressure

3.8K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
3.8K
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

477
Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
477
Assessing Blood pressure in the Leg01:11

Assessing Blood pressure in the Leg

11.3K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
11.3K
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

904
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
904

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reliability and reproducibility of piezoelectric-derived local brachial pulse wave velocity measurement and pressure normalization.

Biomedical physics & engineering express·2026
Same author

CytoCLIP: Learning Cytoarchitectural Characteristics in Developing Human Brain Using Contrastive Language Image Pre-Training.

Neuroinformatics·2026
Same author

AD-DAE: Alzheimer's Disease Progression Modeling with Unpaired Longitudinal MRI using Diffusion Auto-Encoders.

IEEE journal of biomedical and health informatics·2026
Same author

An Image-Free Ultrasound-Based Approach for Combined Assessment of Local and Regional Arterial Stiffness in Humans.

Journal of visualized experiments : JoVE·2026
Same author

Deep Learning-Based Cardiac Output Estimation Using Multimodal Physiological Signals.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Unobtrusive Heart Rate Variability Monitoring with a Chair-Based Strain Gauge Ballistocardiography in Office and Home Settings.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: Feb 20, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
05:51

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness

Published on: May 3, 2018

18.6K

Brachial artery stiffness estimation using ARTSENS.

V Raj Kiran, P M Nabeel, Jayaraj Joseph

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |October 25, 2017
    PubMed
    Summary
    This summary is machine-generated.

    Arterial stiffness, a risk factor for heart and kidney disease, can now be measured using the compact ARTSENS® device. This study confirms its reliable and repeatable measurements of brachial artery stiffness.

    More Related Videos

    Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound
    10:08

    Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound

    Published on: December 2, 2014

    16.5K
    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
    08:42

    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research

    Published on: October 22, 2014

    28.0K

    Related Experiment Videos

    Last Updated: Feb 20, 2026

    Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
    05:51

    Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness

    Published on: May 3, 2018

    18.6K
    Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound
    10:08

    Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound

    Published on: December 2, 2014

    16.5K
    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
    08:42

    Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research

    Published on: October 22, 2014

    28.0K

    Area of Science:

    • Cardiovascular Physiology
    • Medical Imaging Technology
    • Biomedical Engineering

    Background:

    • Arterial stiffening is a significant risk factor for cardiovascular diseases, including coronary heart disease and kidney disease.
    • Current non-invasive methods for assessing arterial stiffness are often costly, require specialized expertise, and are not suitable for widespread screening.
    • There is a need for accessible, portable, and user-friendly devices for evaluating arterial stiffness.

    Purpose of the Study:

    • To demonstrate the feasibility of using the ARTSENS® device for measuring brachial artery stiffness.
    • To assess the inter-operator repeatability and agreement of ARTSENS® measurements for brachial artery stiffness.
    • To validate the performance of ARTSENS® in a clinical setting.

    Main Methods:

    • ARTSENS®, a compact, image-free ultrasound device, was used to measure arterial stiffness parameters.
    • In-vivo experiments were conducted on 9 healthy subjects, with measurements performed successively by two operators.
    • Key parameters measured included distension, end-diastolic lumen diameter, arterial compliance, and stiffness index for both carotid and brachial arteries.
    • Inter-operator agreement was analyzed using Bland-Altman plots and paired t-tests.

    Main Results:

    • ARTSENS® demonstrated high inter-operator repeatability for brachial artery stiffness measurements.
    • No statistically significant differences were found between measurements made by the two operators (p-values > 0.11 for all parameters).
    • A high and significant correlation (r=0.86, p=0.003) was observed between the measurements made by the two operators.

    Conclusions:

    • The ARTSENS® device is feasible for accurate and repeatable measurement of brachial artery stiffness.
    • The device offers a promising solution for accessible and mass screening of arterial stiffness.
    • ARTSENS® has been validated for carotid artery stiffness and shows potential for broader clinical application in cardiovascular health assessment.