Temperature influence on the response at low airflow of a variable orifice flowmeter
Abstract:
In mechanical ventilation, in particular when neonates are ventilated, it is crucial to accurately control the amount of the gas delivered to the patients. Mechanical ventilators are equipped with one of more flowmeters. The signal of the flowmeter is used as feedback to control the amount of gas delivered to the patients. Therefore, the accuracy of the flowmeter plays a crucial role in the accurate adjustment of the gas amount delivered by the ventilator. Among several solutions, variable area orifice meters (VAOMs) have several valuable features (e.g., good accuracy, and adequate frequency response), moreover they have the main advantage, with respect to orifice meters, related to the linearity of the response. Despite of their spread in this field, there are not studies focused on the analysis of the air temperature influence on VAOMs response. This study focuses on this topic by investigating the gas temperature influence on the response of a commercial VAOM. Experiments have been performed at low airflow (up to 1.5 L·min-1) and at four different temperatures (i.e., from 22°C to 38°C) covering the range of interest in the field of artificial ventilation. Results show that the response of the VAOM under test is sensitive to temperature: at constant airflow the higher the temperature the higher the sensor output. This analysis may be useful to add correction to sensor output in order to reject the influence of temperature, so to minimize the measurement error due to this factor.
More Related Videos
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
08:25Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pipe Flowrate Measurement: Problem Solving
Poiseuille's Law and Reynolds Number
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Laminar Flow: Problem Solving