Related Experiment Video
Updated: Feb 20, 2026

Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale Entropy
Published on: June 27, 2013
Multiscale sample entropy of heart rate and blood pressure: Methodological aspects
Abstract:
The entropy of heart rate variability is one of the main features characterizing the complexity of the cardiovascular system. In order to take into account the multiscale nature of cardiovascular regulation, it was proposed to evaluate entropy with a multiscale approach, based on the estimation of Sample Entropy on progressively coarse-grained series (Multiscale Sample Entropy, MSE). Aim of this work is to investigate two methodological aspects related to MSE of cardiovascular signals. The first aspect regards the tolerance below which a couple of points are considered similar in a given embedding dimension, in particular how the way the tolerance is set at each level of coarse graining influences the MSE estimates. The second aspect regards whether heart rate and blood pressure (BP) signals are characterized by different MSE structures.To investigate these aspects, we analyzed 65 continuous BP recordings of more than 90-minute duration in healthy volunteers sitting at rest, and applied MSE estimators to beat-by-beat series of systolic BP, diastolic BP and pulse interval (inverse of heart rate). Results indicate that the way the tolerance is set during coarse graining influences substantially the MSE profile of cardiovascular signals, modifying the relative level of their unpredictability.
More Related Videos
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
08:08Using Wavelet Entropy to Demonstrate how Mindfulness Practice Increases Coordination between Irregular Cerebral and Cardiac Activities
Published on: May 10, 2017
Related Concept Videos
Measurement of Blood Pressure
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...