Low group delay signal conditioning for wearable central blood pressure monitoring device
Abstract:
Pulse transit time (ptt) is a widely researched approach for wearable, unobtrusive, blood pressure monitoring. The estimation of ptt, being a delay measurement, may be affected by the group delay introduced by the signal conditioning chain. In this work a previously reported method for estimating central (aortic) blood pressure from ptt at aortic domain, using ECG R wave and BCG J wave detection, is considered. A simple design approach for the signal conditioning chain, which is suitable for a wearable device and that takes care of minimizing the impact of eventually introduced spurious delays is presented. The design provides less than 2ms group-delay. The design of a wearable device prototype for ECG, BCG and ptt acquisition and experimental results of its application are reported, showing the effectiveness of the proposed approach.
More Related Videos
05:32A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring pulse