Related Experiment Video
Updated: Feb 20, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
A novel mainstream capnometer system for endoscopy delivering oxygen.
The cap-ONE Biteblock accurately measures carbon dioxide (CO2) during endoscopy, even with oxygen (O2) supplementation. This new device efficiently supplies O2 while ensuring precise CO2 monitoring, outperforming conventional methods in bench tests.
Area of Science:
- Anesthesiology
- Respiratory Monitoring
- Medical Device Technology
Background:
- Capnometry, measuring exhaled carbon dioxide (CO2), monitors respiratory status.
- Monitoring CO2 during endoscopy detects drug-induced respiratory depression.
- Oxygen (O2) administration during endoscopy can interfere with accurate CO2 measurement.
Purpose of the Study:
- To develop and evaluate the cap-ONE Biteblock, a novel device for accurate CO2 measurement during endoscopy with O2 supply.
- To assess the performance of the cap-ONE Biteblock system in comparison to conventional devices.
Main Methods:
- A bench study was conducted to evaluate the basic performance of the cap-ONE Biteblock.
- The system's ability to accurately measure CO2 and efficiently supply O2 was assessed.
Main Results:
- The cap-ONE Biteblock system demonstrated accurate CO2 measurement capabilities.
- The device efficiently supplied O2, indicating its suitability for use during procedures with oxygen supplementation.
- Performance was favorable when compared to conventional devices in the bench study.
Conclusions:
- The cap-ONE Biteblock is a promising device for accurate capnometry in patients undergoing endoscopy with oxygen supplementation.
- It effectively overcomes the interference issues associated with oxygen flow during CO2 monitoring.
- This technology can improve patient safety by ensuring reliable respiratory status assessment during endoscopic procedures.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...