Related Experiment Video
Updated: Feb 20, 2026

Determining heat and mechanical pain threshold in inflamed skin of human subjects
Published on: January 14, 2009
Development of a "Thermal-Associated Pain Index" score using infrared-thermography for objective pain assessment
Abstract:
Without any doubt, research in biomedical engineering and anesthesiology achieved diverse ground-breaking successes for the sake of patient safety and for optimization of medical treatment in the last decades. Particularly anesthesia has become increasingly comfortable and safer due to new monitoring devices and further techniques. However, assessment of pain still relies on self-reporting of the patient using a Numeric Rating Scale ranging from 0 to 10. Obviously, this method suffers from severe restraints when unconscious, anesthetized or uncooperative subjects or children are involved as patients. Furthermore, no continuous monitoring is available so that features like alerting telemetry are lacking. Several scientific groups and companies searched intensively for procedures to measure pain objectively. Skin conductance, heart rate variability and peripheral perfusion, among others, were used to develop new algorithms and devices. Up to date, none of these devices succeeded to enter in clinical routine. In this project, we used infrared thermography (IRT) to analyze facial expressions and further thermal-associated phenomena that are visible in recorded IRT sequences such as lacrimation and perspiration. By means of clinical observations, a number of IRT features were predefined that were expected to correlate with pain. The combination of those features led to the so-called "Thermal-Associated Pain Intensity" (TAPI) after normalization and transformation. The TAPI correlates significantly with the NRS and achieves a sensitivity of above 0.75 to detect pain.
Related Concept Videos
Thermosensation
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...