Ali M Al-Mashani1, Niranjan D Waje2, Neeraj Salhotra1
1Departments of Neurosurgery, Intensive Care Unit & Pain Management, Khoula Hospital, Muscat, Oman.
Abstract:
Patients with mitral valve disease undergoing cerebrovascular surgery face increased inherent risks due to their associated cardiac comorbidities. As such, the anaesthetic management of such patients is distinctly challenging. Simultaneous consideration of both the cerebrovascular and underlying cardiac conditions determines key anaesthetic issues, as fluids and vasopressors or inotropes need to be titrated according to haemodynamic variables in order to optimise cerebral blood flow without compromising cardiac function. We report a 45-year-old female patient with mild mitral stenosis and moderate-to-severe mitral regurgitation who presented to the Khoula Hospital, Muscat, Oman, in 2016 following a ruptured anterior communicating artery aneurysm requiring urgent surgical intervention. As highlighted in this case, the VolumeView EV1000™ (Edwards Lifesciences, Irvine, California, USA) system is a minimially invasive haemodynamic monitor that can help immensely in the perioperative management of such patients.
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Mitral Stenosis IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Mitral Regurgitation IV: Nursing Management