Patrick D McLaughlin1, Liam Chawke2, Maria Twomey2,3
1Department of Emergency and Trauma Radiology, Vancouver General Hospital, Jim Pattison Pavilion North, #3350-950 West 10th Ave, Vancouver, BC, V5Z 1M9, Canada.
Objectives:
We designed a prospective study to investigate the in-vivo relationship between abdominal body composition and radiation exposure to determine the strongest body composition predictor of dose length product (DLP) at CT.
Methods:
Following institutional review board approval, quantitative analysis was performed prospectively on 239 consecutive patients who underwent abdominopelvic CT. DLP, BMI, volumes of abdominal adipose tissue, muscle, bone and solid organs were recorded.
Results:
All measured body composition parameters correlated positively with DLP. Linear regression (R2 = 0.77) revealed that total adipose volume was the strongest predictor of radiation exposure [B (95% CI) = 0.027(0.024-0.030), t=23.068, p < 0.001]. Stepwise linear regression using DLP as the dependent and BMI and total adipose tissue as independent variables demonstrated that total adipose tissue is more predictive of DLP than BMI [B (95% CI) = 16.045 (11.337-20.752), t=6.681, p < 0.001].
Conclusions:
The volume of adipose tissue was the strongest predictor of radiation exposure in our cohort.
Main Message:
• Individual body composition variables correlate with DLP at abdominopelvic CT. • Total abdominal adipose tissue is the strongest predictor of radiation exposure. • Muscle volume is also a significant but weaker predictor of DLP.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
13:35Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
Published on: March 21, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Biological Effects of Radiation
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...