Assessment of Coded Excitation Implementation for Estimating Heat-Induced Speed of Sound Changes
Oren Gargir1, Haim Azhari1, Michael Zibulevsky2
1Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
Abstract:
Speed of sound (SoS) is an acoustic property that is highly sensitive to changes in tissues. SoS can be mapped non-invasively using ultrasonic through transmission wave tomography. This however, practically limits its clinical use to the breast. A pulse-echo-based method that has broader clinical use and that can reliably measure treatment-induced changes in SoS even under poor signal-to-noise ratio (SNR) is highly desirable. The aim of this study was to evaluate the implementation of coded excitations (CoEs) to improve pulse-echo monitoring of heat-induced changes in the SoS. In this study, a binary phase modulated Barker sequence and a linear frequency-modulated chirp were compared with a common Gaussian pulse transmission. The comparison was conducted using computer simulations, as well as transmissions in both agar-gelatin phantoms and ex vivo bovine liver. SoS changes were experimentally induced by heating the specimens with a therapeutic ultrasound system. The performance of each transmission signal was evaluated by correlating the relative echo shifts to the normalized SoS measured by through transmission. The computer simulations indicated that CoEs are beneficial at very low SNR. The Barker code performed better than both the chirp and Gaussian pulses, particularly at SNRs <10 dB (R2 = 0.81 ± 0.06, 0.68 ± 0.07 and 0.55 ± 0.08, respectively, at 0 dB). At high SNRs, the CoEs performed statistically on par with the Gaussian pulse. The experimental findings indicated that both Barker and chirp codes performed better than the Gaussian pulse on ex vivo liver (R2 = 0.80 ± 0.15, 0.79 ± 0.15 and 0.54 ± 0.17, respectively) and comparably on agar-gelatin phantoms. In conclusion, CoEs can be beneficial for assessing temperature-induced changes in the SoS using the pulse-echo method under poor SNR.
More Related Videos
09:38Quantitative Assessment of Cortical Auditory-tactile Processing in Children with Disabilities
Published on: January 29, 2014
10:50Behavioral Determination of Stimulus Pair Discrimination of Auditory Acoustic and Electrical Stimuli Using a Classical Conditioning and Heart-rate Approach
Published on: June 6, 2012
Related Concept Videos
Quantifying Heat
Deriving the Speed of Sound in a Liquid
The speed of sound in fluids can be derived by considering a mechanical wave...
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Speed of Sound in Gases
Heat Flow and Specific Heat