Determination of PM2.5 Sulfate and Nitrate with a PC-BOSS Designed for Routine Sampling for Semi-Volatile Particulate
Delbert J Eatough1, Yanbo Pang1, Norman L Eatough2
1a Department of Chemistry and Biochemistry , Brigham Young University , Provo , Utah , USA.
Abstract:
Ambient particles contain substantial quantities of material that can be lost from the particles during sample collection on a filter. These include ammonium nitrate and semi-volatile organic compounds. As a result, the concentrations of these species are often significantly in error for results obtained with a filter pack sampler. The accurate measurement of these semi-volatile fine particulate species is essential for a complete understanding of the possible causes of health effects associated with exposure to fine particles. Past organic compound diffusion denuder samplers developed by the authors (e.g., the Brigham Young University Organic Sampling System [BOSS]) are not amenable to routine field use because of the need to independently determine the gas-phase semi-volatile organic material efficiency of the denuder for each sample. This problem has been eliminated using a combined virtual impactor, particle-concentrator inlet to provide a concentrated stream of 0.1-2.5-μm particles. This is followed by a BOSS diffusion denuder and filter packs to collect particles, including any semi-volatile species lost from the particles during sampling. The samp ler (Particle Concentrator-Brigham Young University Organic Sampling System [PC-BOSS]) contains a post-denuder multifilter pack unit to allow for the routine collection of several sequential samples. The PC-BOSS can be used for the determination of both fine particulate nitrate and semi-volatile organic material without significant "positive" or "negative" sampling artifacts. Validation of the sampler for the determination of PM2.5 sulfate and nitrate based on comparison of results obtained at Riverside, CA with collocated PC-BOSS, annular denuder, and Chem Spec samplers indicates the PC-BOSS gives accurate results for these species with a precision of ±5-8%. An average of 33% of the PM2.5 nitrate was lost from the particles during sampling for both denuder and single filter samplers.
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Precipitation and Co-precipitation