Related Experiment Video
Updated: Feb 20, 2026

Simplified Whole Body Plethysmography to Characterize Lung Function During Respiratory Melioidosis
Published on: February 24, 2023
Waterpipe cafés are hazardous to your health: Determination of a waterpipe specific calibration factor
Mark J Travers1, Jessica A Kulak2, Lisa Vogl1
1Department of Health Behavior and Air Pollution Exposure Research Laboratory, Roswell Park Cancer Institute, Buffalo, NY, USA.
Introduction:
The use of a waterpipe to smoke tobacco has emerged as a popular trend in the United States. Waterpipe smoking establishments have had an increasing presence in the U.S., despite smoke-free air legislation. Dangers of waterpipe smoking have been documented, but less data has been gathered about the waterpipe café itself. This project sought to determine a waterpipe-specific calibration factor (CF) for measuring waterpipe aerosol, and field-test this CF by conducting surveillance on the existing waterpipe cafés of western and central New York.
Methods:
Nine laboratory-controlled experiments were conducted to determine a waterpipe-specific CF. In the lab, two TSI SidePak AM510 Personal Aerosol Monitors and two sampling trains for gravimetric PM2.5 sampling were present during waterpipe smoking sessions (lasting 1-3h). Indoor air quality was assessed in 7 waterpipe cafés in three counties of New York, and real-time measurements of particulate matter (PM2.5) and carbon monoxide (CO) were obtained.
Results:
Results from the 9 controlled waterpipe experiments determined a calibration factor of 0.38 (SD 0.08), which should be used to convert SidePak measurements to true PM2.5 measurements. When applying the CF to the measurements taken in the 7 public waterpipe venues, the mean PM2.5 concentration was 515μg/m3 micrograms per cubic meter (SD=338.8) while the mean ambient CO was 20.5ppm (SD=18.3). The mean active smoking density was 2.41 waterpipes per 100m3 of air. The PM2.5 levels increased with increasing active smoking density (rho=0.68, p=0.09).
Conclusions:
Applying the waterpipe-specific CF for the SidePak, 0.38, allowed for field assessments to be conducted in locations with waterpipe smoke to determine accurate particle exposure concentrations. The concentrations of both particulate matter and carbon monoxide were above established air quality standards and therefore increase the health risks of both patrons and workers of these establishments.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
10:20Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
Related Concept Videos
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Pipe Flowrate Measurement: Problem Solving
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Design Example: Designing a Residential Plumbing System