Related Experiment Video
Updated: Feb 20, 2026

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
Published on: December 15, 2023
Reliability of CSF turbulence and choroid plexus visualization on fast-sequence MRI in pediatric hydrocephalus
Curtis J Rozzelle1, Casey Madura2, Ron W Reeder3
11Department of Neurosurgery, Division of Pediatric Neurosurgery, The University of Alabama at Birmingham and Children's of Alabama, Birmingham.
Abstract:
OBJECTIVE Endoscopic third ventriculostomy with choroid plexus cauterization for the treatment of neonatal and infant hydrocephalus has gained popularity in the past decade. Identifying treatment failure is critically important. Results of a pilot study of 2 novel imaging markers seen on fast-sequence T2-weighted axial MRI showed potential clinical utility. However, the reliability of multiple raters detecting these markers must be established before a multicenter validation study can be performed. METHODS Two sets of de-identified single-shot T2-weighted turbo spin-echo axial images were prepared from scans of patients before and after they underwent endoscopic third ventriculostomy with choroid plexus cauterization between March 2013 and January 2016. The first set showed the lateral and third ventricles for visualization of turbulent CSF dynamics, and the second set showed the lateral ventricular atria for choroid plexus glomus detection. Three raters (Group 1) received written instructions before evaluating each image set once and then again 1 week later. Another 8 raters (Group 2) evaluated both image sets after oral instruction and group training on a pretest image set. Fleiss' kappa coefficients with 95% CIs were calculated for intrarater and interrater reliability in Group 1 and interrater reliability in Group 2. RESULTS Intrarater reliability kappa coefficients for Group 1 were ≥ 0.74 for turbulence and ≥ 0.80 for choroid plexus; their interrater kappa coefficients at the initial assessment were 0.50 (95% CI 0.37-0.62) and 0.56 (95% CI 0.43-0.69), respectively. The Group 2 interrater kappa scores were 0.82 (95% CI 0.78-0.86) for turbulence and 0.62 (95% CI 0.58-0.66) for choroid plexus. CONCLUSIONS With minimal training, intrarater reliability on visualization of turbulence and the choroid plexus was substantial, but interrater reliability was only moderate. After modestly increasing training, interrater reliability improved to near perfect and to substantial reliability for visualization of turbulence and choroid plexus, respectively. Given adequately trained observers, a multicenter investigation into the validity and potential clinical utility of the imaging markers seems feasible.
More Related Videos
06:22In Vivo Imaging of Cerebrospinal Fluid Transport through the Intact Mouse Skull using Fluorescence Macroscopy
Published on: July 29, 2019
10:41Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound