Identifying Hemodynamic Determinants of Pulse Pressure: A Combined Numerical and Physiological Approach
Samuel Vennin1, Ye Li1, Marie Willemet1
1From the King's College London British Heart Foundation Centre, Department of Clinical Pharmacology (S.V., Y.L., H.F., H.G., P.C.) and Division of Imaging Sciences and Biomedical Engineering (S.V., Y.L., M.W., P.C., J.A.), King's College London, St Thomas' Hospital, London, United Kingdom.
Abstract:
We examined the ability of a simple reduced model comprising a proximal characteristic impedance linked to a Windkessel element to accurately predict central pulse pressure (PP) from aortic blood flow, verified that parameters of the model corresponded to physical properties, and applied the model to examine PP dependence on cardiac and vascular properties. PP obtained from the reduced model was compared with theoretical values obtained in silico and measured values in vivo. Theoretical values were obtained using a distributed multisegment model in a population of virtual (computed) subjects in which cardiovascular properties were varied over the pathophysiological range. In vivo measurements were in normotensive subjects during modulation of physiology with vasoactive drugs and in hypertensive subjects. Central PP derived from the reduced model agreed with theoretical values (mean difference±SD, -0.09±1.96 mm Hg) and with measured values (mean differences -1.95±3.74 and -1.18±3.67 mm Hg for normotensive and hypertensive subjects, respectively). Parameters extracted from the reduced model agreed closely with theoretical and measured physical properties. Central PP was seen to be determined mainly by total arterial compliance (inversely associated with central arterial stiffness) and ventricular dynamics: the blood volume ejected by the ventricle into the aorta up to time of peak pressure and blood flow into the aorta (corresponding to the rate of ventricular ejection) up to this time point. Increased flow and volume accounted for 20.1 mm Hg (52%) of the 39.0 mm Hg difference in PP between the upper and lower tertiles of the hypertensive subjects.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.