Related Experiment Video
Updated: Feb 19, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Detections of Screw Penetration during Volar Plating for Distal Radius Fractures
1Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University, School of Medicine, Daejeon, Korea.
Abstract:
Background We evaluated the detection for screw penetration on the dorsal cortex of the radius in serial oblique, dorsal tangential, and radial groove radiographic views in volar plating fixation. Materials and Methods Eight screw positions were set in each of the four cadaveric radii. Screw 1 was placed in the styloid subregion, whereas screws 2 and 3 were placed just proximal to the styloid and were defined for the radial region of the radius. Screws 4 (distal to the extensor pollicis longus [EPL] groove), 5 (the distal half of the groove), and 6 (the proximal half of the groove) were placed in the central region of the radius. Screws 7 (just medial to the groove) and 8 (sigmoid notch subregion) were positioned in the ulnar region of the radius. The screws were overlengthened by 1 and 2 mm and were evaluated in three radiographic views. Results Penetrations in the radial region were fully visible in supinated oblique views with 1- and 2-mm overlengthened screws. The penetration of screw 4 was clearly observable over a considerable range of views. However, the 1-mm penetration of screw 5 was not detectable at any angle of projection. Detection of the ulnar region screw was the most difficult among the three regions with oblique views. In the dorsal tangential view, the 1-mm penetration of screw 4 was not observed in any of the four radii, but the penetration of screw 5 was detectable in all the radii. The screws 2, 3, 5, 7, and 8 were readily detectable. The screw 4 was barely seen in the radial groove view, while the screws 5 and 6 were readily detectable. Conclusion/Clinical Relevance Appropriate combinations of these well-known radiological views are essential for the overall detection of penetrated screws during plating in distal radius fractures.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation