Maternal cardiac output response to colloid preload and vasopressor therapy during spinal anaesthesia for caesarean
R A Dyer1, A Daniels1, A Vorster1
1Department of Anaesthesia and Peri-operative Medicine, University of Cape Town, Cape Town, South Africa.
We examined the haemodynamic effects of colloid preload, and phenylephrine and ephedrine administered for spinal hypotension, during caesarean section in 42 women with severe early onset pre-eclampsia. Twenty patients with pre-delivery spinal hypotension were randomly allocated to receive an initial dose of either 50 μg phenylephrine or 7.5 mg ephedrine; the primary outcome was percentage change in cardiac index. After a 300-ml colloid preload, mean (SD) cardiac index increased from 4.9 (1.1) to 5.6 (1.2) l.min-1 .m-2 (p < 0.01), resulting from an increase in both heart rate, from 81.3 (17.2) to 86.3 (16.5) beats.min-1 (p = 0.2), and stroke volume, from 111.8 (19.0) to 119.8 (17.9) ml (p = 0.049). Fourteen (33%) and 23 (54.8%) patients exhibited a stroke volume response > 10% and > 5%, respectively; a significant negative correlation was found between heart rate and stroke volume changes. Spinal hypotension in 20 patients was associated with an increase from baseline in cardiac index of 0.6 l.min-1 .m-2 (mean difference 11.5%; p < 0.0001). After a median [range] dose of 50 [50-150] μg phenylephrine or 15 [7.5-37.5] mg ephedrine, the percentage change in cardiac index during the measurement period of 150 s was greater, and negative, in patients receiving phenylephrine vs. ephedrine, at -12.0 (7.3)% vs. 2.6 (6.0)%, respectively (p = 0.0001). The percentage change in heart rate after vasopressor was higher in patients receiving phenylephrine, at -9.1 (3.4)% vs. 5.3 (12.6)% (p = 0.0027), as was the change in systemic vascular resistance, at 22.3 (7.5) vs. -1.9 (10.5)% (p < 0.0001). Phenylephrine effectively reverses spinal anaesthesia-induced haemodynamic changes in severe pre-eclampsia, if left ventricular systolic function is preserved.
We examined the haemodynamic effects of colloid preload, and phenylephrine and ephedrine administered for spinal hypotension, during caesarean section in 42 women with severe early onset pre-eclampsia. Twenty patients with pre-delivery spinal hypotension were randomly allocated to receive an initial dose of either 50 μg phenylephrine or 7.5 mg ephedrine; the primary outcome was percentage change in cardiac index. After a 300-ml colloid preload, mean (SD) cardiac index increased from 4.9 (1.1) to 5.6 (1.2) l.min-1 .m-2 (p < 0.01), resulting from an increase in both heart rate, from 81.3 (17.2) to 86.3 (16.5) beats.min-1 (p = 0.2), and stroke volume, from 111.8 (19.0) to 119.8 (17.9) ml (p = 0.049). Fourteen (33%) and 23 (54.8%) patients exhibited a stroke volume response > 10% and > 5%, respectively; a significant negative correlation was found between heart rate and stroke volume changes. Spinal hypotension in 20 patients was associated with an increase from baseline in cardiac index of 0.6 l.min-1 .m-2 (mean difference 11.5%; p < 0.0001). After a median [range] dose of 50 [50-150] μg phenylephrine or 15 [7.5-37.5] mg ephedrine, the percentage change in cardiac index during the measurement period of 150 s was greater, and negative, in patients receiving phenylephrine vs. ephedrine, at -12.0 (7.3)% vs. 2.6 (6.0)%, respectively (p = 0.0001). The percentage change in heart rate after vasopressor was higher in patients receiving phenylephrine, at -9.1 (3.4)% vs. 5.3 (12.6)% (p = 0.0027), as was the change in systemic vascular resistance, at 22.3 (7.5) vs. -1.9 (10.5)% (p < 0.0001). Phenylephrine effectively reverses spinal anaesthesia-induced haemodynamic changes in severe pre-eclampsia, if left ventricular systolic function is preserved.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiopulmonary Resuscitation IV: Pharmacological Management
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...