[Simultaneous determination of thirteen components in Tong'an injection by LC-MS/MS]
Chan Shang1, Meng-Xuan Li2, Hai-Bo Li2
1School of Chinese Materia Medica, China Pharmaceutical University, Nanjing 211198, China.
Abstract:
The aim of this study was to develop a simple, sensitive ultra performance liquid chromatography mass spectrometry (UPLC-MS/MS) method for the determination of syringaresinol, N-trans-feruloyltyramine, chelerythrine chloride, sinomenine, coptisine chloride, sanguinarine, chelidonine, magnolflorine, allocryptopine, protopine, farrerol, stylopine and dihydrosanguin-arine in Tong'an injection (TAI), which could be used for the quality control of TAI. The UPLC analysis was performed on Agilent Zorbax SB-Aq column (2.1 mm×150 mm,3.5 μm), with 0.1% formic acid solution (A) -acetonitrile (B) as the mobile phase for gradient elution (0.01-2 min, 5%B; 2-8 min, 5%-30%B; 8-11 min, 30%-95%B; 11-13 min, 95%B; 13-13.1 min, 95%-5%B; 13.1-14 min, 5%B). The flow rate was 0.5 mL•min⁻¹, and the column temperature was 25 ℃; multiple reaction monitoring (MRM) was performed in electrospray ion source positive ion mode for quantitative determination. The calibration curves for the above thirteen compounds showed good linear relationship in corresponding mass concentration range (r>0.999 0). The average recovery rate of the compounds ranged from 95.70% to 104.8%, with RSD of less than 1.9%. The contents of thirteen active components in 10 batches of TAI were 0.021 2-0.029 0, 0.001 7-0.002 3, 0.000 9-0.001 3, 5.952-6.205 2, 0.195 4-0.240 5, 0.002 0-0.002 9, 0.693-0.798 2, 0.069 3-0.078 2, 0.089 29-0.102 9, 0.386 5-0.420 1, 0.014 3-0.015 9, 0.755 3-0.842 1, and 0.008 2-0.011 2 g•L⁻¹ respectively. Methodology validation proved that this method was simple, rapid, sensitive and accurate, which can be used to provide reference for the comprehensive evaluation of TAI quality. The determination results of 10 batches of TAI showed the content of each batch had no significant difference. The results may provide a basis for the quality control of TAI.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...