Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
134Cs activity standardization by 4πβ(LS)-γ(NaI-Tl) anticoincidence counting and submission to international
C J da Silva1, Paulo A L da Cruz1, A Iwahara1
1Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Instituto de Radioproteção e Dosimetria (IRD), Comissão Nacional de Energia Nuclear (CNEN), Av. Salvador Allende, s/no - Barra da Tijuca, CEP 22783-127 Rio de Janeiro, Brazil.
Abstract:
From a commercial supplier a solution containing 134Cs has been standardized at National Laboratory for Ionizing Radiation Metrology (LNMRI) for the first time using three Liquid scintillation based measurement. These measurement methods are 4πβ-γ live-timed anticoincidence counting, 4πβ-γ coincidence counting and 3H-standard efficiency tracing with the CNET methods. The results obtained by anticoincidence counting was adopted as reference value and its combined uncertainty was 0.38%. The agreement of this reference value with coincidence counting and CNET methods were 0.39% and 0.34% respectively and were in consistency with each uncertainty method. The weighted mean results coincidence counting and CNET methods are also in close agreement 0.03% with anticoincidence counting method and meets the requirement of primary and national standard. This standardization was made in order to reduce the uncertainty in 134Cs measurement in Brazil and also following a request made by Bureau International des Poids and Mesures for new submission to International Reference System. The LNMRI last submission was made in 1987. Therefore from a 134Cs master solution a NIST ampoules was prepared and LNMRI/IRD submitted it to the International Reference System, Bureau International of Poids and Measures (SIR/BIPM). In this paper will be analyzed the LNMRI measurement and performance each measurement methods and also take into account the reference value of KCDB, we determined also the 134Cs gamma emission probabilities of main energy.
More Related Videos
08:40Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure
Published on: March 21, 2017
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Radioactive Decay and Radiometric Dating