Kavitha G1, Pallavi K Kakade2, Madhavi Singh3
1Department of Conservative Dentistry and Endodontics Sharavathi Dental College, Shimoga, Karnataka, India, Phone: +919501544877,
Introduction:
Capnography is routinely used for monitoring of patients subjected to sedation for different surgical procedures. There is still paucity of data highlighting the capnographic assessment of patients on midazolam sedation undergoing oral surgical procedures. Hence, we planned the present study to assess the alterations occurring in the end-tidal carbon dioxide (ETCO2) values monitored during intravenous (IV) sedation with midazolam during various oral surgical procedures.
Materials And Methods:
The present study included assessment of alteration in ETCO2 values occurring during oral surgical procedure. After meeting the inclusion and exclusion criteria, a total of 40 participants were included in the present study. Pulse oximeter with capnograph (EmcoMeditek Pvt., Ltd., India) device was used for assessment of respiratory rate (RR) and ETCO2 values. The mean of 12 readings over a period of 1 minute before the starting of first infusion was referred to as baseline time. By evaluating the first four readings at an interval of 15 seconds during the 1st minute of infusion, we obtained the 1 minute average reading. All the data were compiled and recorded and assessed by the Statistical Package for the Social Sciences (SPSS) software.
Results:
A total of 40 participants were included, out of which, 20 were males and 20 were females. At the baseline time, mean value of ETCO2 was 31 mm Hg, while mean value of oxygen saturation (SpO2) was 36%. Out of total 40 participants, 15 showed the presence of respiratory depression. Out of these 15 participants, ETCO2 changes from baseline were observed in 13 participants.
Conclusion:
No oxygen should be delivered, unless until required, to the healthy participants undergoing dental sedation procedures, for marinating the sensitivity of pulse oximetry during assessment of respiratory depression.
Clinical Significance:
In patients undergoing sedation procedures, various monitoring techniques should be employed as respiratory depression is a commonly encountered risk factor.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
08:49Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
Related Concept Videos
Stages of General Anesthesia
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Parenteral Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Inhalational Anesthetics: Overview