Related Experiment Video
Updated: Feb 19, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Intravoxel Incoherent Motion Analysis of Abdominal Organs: Application of Simultaneous Multislice Acquisition
Valerie Doan Phi Van1, Anton S Becker, Alexander Ciritsis
1From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Purpose:
The aim of this study was to systematically evaluate the accuracy of quantitative intravoxel incoherent motion (IVIM) analysis of the upper abdomen applying simultaneous multislice (SMS) diffusion-weighted imaging (DWI) to reduce acquisition time.
Materials And Methods:
Diffusion-weighted imaging of parenchymal abdominal organs was performed in 8 healthy volunteers at 3 T using a standard DWI sequence (acceleration factor 1 [AF1]) and an SMS-accelerated echo planar imaging sequence with acceleration factors 2 and 3 (AF2/AF3). Intravoxel incoherent motion analysis was performed with a multistep algorithm for true diffusion coefficient (Dt), pseudodiffusion coefficient (D*), and fraction of perfusion (Fp) measured for the liver, kidney cortex and medulla, pancreas, spleen, and erector spinae muscle. Qualitative and quantitative parameters were compared using a repeated measurement 1-way analysis of variance test and the Bonferroni post hoc method.
Results:
Simultaneous multislice DWI provided diagnostic image quality in all volunteers with a reduction of scan time of 50% for AF2 (67% for AF3) compared with the standard sequence. Decent IVIM analysis for Dt, D*, and Fp can be calculated on the images of both the SMS sequences AF2 and AF3 with typical organ characteristics of IVIM; however, systematical deviations from AF1 were observed: Dt values increased and Fp decreased significantly with higher acceleration factor for liver, kidney, pancreas, and muscle (P < 0.05). Fitting curves of higher acceleration factors tend to be more monoexponentially shaped.
Conclusions:
Simultaneous multislice acceleration provides considerable scan time reduction for upper abdomen DWI with equivalent quality of IVIM analysis compared with the standard nonaccelerated technique. Systematic discrepancies of the true Dt, D*, and Fp for SMS acquisitions need to be considered when comparing to standard DWI sequences.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...