Related Experiment Video
Updated: Feb 19, 2026

Quantitative Autonomic Testing
Published on: July 19, 2011
Cardiac autonomic neuropathy in type 2 diabetes mellitus using Bellavere's score system
1Department of Medicine, Unaizah College of Medicine, Qassim University, Unaizah, Saudi Arabia.
Objective:
Determine the frequency of cardiac autonomic neuropathy (CAN) in type 2 diabetics using Bellavere's score system.
Subjects And Methods:
The present cross-sectional study was conducted at the Department of Medicine, Isra University Hospital Hyderabad from March to November 2011. Sixty voluntary participants of type 2 diabetes mellitus (DM) were selected through non-probability purposive sampling. Cardiac autonomic nerve function was assessed using Bellavere's score system. The data were analyzed on the Statistix version 10.0 (USA) using Student's t-test, Chi-square test, one-way ANOVA, and Tukey-Cramer test (P ≤ 0.05).
Results:
Of 60 diabetics, CAN was observed in 29 (41.4%). Abnormal heart rate variability (HRV), valsalva ratio, 30-15th ratio, blood pressure (BP) response to standing, and handgrip was noted in 43 (61.4%), 27 (38.5%), 17 (24.2%), 5 (7.14%), and 18 (25.7%), respectively. The hemoglobin A1c was negative correlated with HRV, valsalva ratio, 30-15th ratio, and BP response to sustained handgrip; and positively correlated with BP response to standing, systolic BP, and diastolic BP. Duration of DM was not correlated with cardiac autonomic nerve function tests.
Conclusion:
The CAN was observed in 29 (41.4%) using Bellavere's score system. The CAN score may be used as feasible and reproducible bedside clinical test in diabetic patients.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes Mellitus: Type 2 and Gestational
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiomyopathy II: Dilated Cardiomyopathy
Disorders of the Autonomic Nervous System
Raynaud's disease, also known as Raynaud's...

