Challenges of Cerebral Perfusion Pressure Measurement
Sarah L Livesay1, Molly M McNett, Monica Keller
1Questions or comments about this article may be directed to Sarah L. Livesay, DNP RN ACNP-BC ACNS-BC, at sarah_l_livesay@rush.edu. She is an Associate Professor, Department of Adult and Gerontological Nursing, Rush University College of Nursing, Chicago, IL. Molly M. McNett, PhD RN, is Director, MetroHealth, Cleveland, OH. Monica Keller, BSN RN, is Staff Nurse, UT Southwestern, Dallas, TX. DaiWai M. Olson, PhD RN, is Associate Professor, Department of Neurology, Neurotherapeutics, and Neurological Surgery, UT Southwestern, Dallas, TX.
Abstract:
Monitoring cerebral perfusion pressure (CPP) is recommended by a number of clinical practice guidelines and is a routine function performed by critical care neuroscience nurses. However, several studies highlight theoretical and practice variations in the measurement of CPP regarding the location of the arterial pressure transducer during measurement. Agreement on the technique and process for obtaining valid measurements is lacking. This article identifies the challenges associated with CPP measurement and highlights opportunities for standardizing CPP measurement to improve consistency in care and findings reported in the research literature. The challenges associated with practice variations impact multiple nursing domains, including the environment, patient treatment, and team communication; all ultimately impacting nursing workflow. The practice variation and impact on nursing workflow have significant implications for further research, electronic health record development, and refining monitoring technology.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)