Related Experiment Video
Updated: Dec 31, 2025

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Metallic Mercury Injection in the Hand Caused by A Broken Mercury Thermometer: A Case Report
Dongmin Kim1, Jong Woong Park1
11 Department of Orthopedic Surgery, College of Medicine, Korea University, Seoul, Korea.
Abstract:
Incorrect usage of or accidents related to metallic mercury can be hazardous. Herein, we present a case of subcutaneous metallic mercury injection in the hand caused by a broken thermometer and surgical tips for this injury. A 43-year-old female patient visited our hospital due to mercurial injection injury at the left hand suffered 4 weeks previously. On gross findings, the mercury deposition was limited to the subcutaneous layer and enveloped by granulation tissue. The blood mercury level, which had been abnormally elevated, fortunately decreased to within normal levels within five months. Nonetheless, this initial elevation indicates the possibility of systemic complications after local absorption of mercury droplets into the general circulation. In conclusion, we recommend prompt and complete excision of mercury material to prevent local and systemic complications, and excising the granulation tissue in its entirety, while retaining the mercury droplets within, is recommended.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...