Objective measurement of spectacle wear with a temperature sensor data logger
Matthew J Lentsch1, Jason D Marsack1, Heather A Anderson1
1College of Optometry, University of Houston, Texas, USA.
Purpose:
This study seeks to establish the utility of the SmartButton Data Logger (www.acrsystems.com) to monitor spectacle wear for research and clinical applications.
Methods:
Fifty adults wore a thermosensor on their spectacles for 2 weeks for each of two mount types while keeping wear-time logs. Temperatures during reported spectacle wear (ON) were compared to temperatures during non-wear (OFF) with repeated measures analysis of variance (ANOVA). In addition, two strategies to approximate spectacle wear from temperature data were evaluated: (1) Filtering data based on temperature ranges to identify spectacle wear (either group mean ON temperature, or an individual's mean ON temperature), and (2) Separate examiners inspecting temperature against time plots to identify spectacle wear. The success of these methods to approximate wear time was evaluated by per cent error with respect to subject reported wear time.
Results:
Group mean ON (31.8 [0.6]°Celsius [°C]) and OFF (24.7 [1.5]°C) temperatures differed significantly (F1,47 = 471.2, p < 0.001), but there was no difference in temperature between mounts (F1,47 = 1.9, p = 0.18). Median per cent error and first and third quartiles (Q1, Q3) of each technique used to approximate wear time were: group mean filtering = 8% (Q1 3%, Q3 18%), individual mean filtering = 7% (Q1 4%, Q3 19%), Examiner 1 = 6% (Q1 2%, Q3 14%), Examiner 2 = 7% (Q1 3%, Q3 12%).
Conclusions:
The SmartButton can monitor spectacle compliance in patients with all approximation methods evaluated providing less than 10% median per cent error in wear time.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermosensation
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...