Related Experiment Video
Updated: Feb 19, 2026

Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Tissue Doppler assessment of diastolic function and relationship with mortality in critically ill septic patients: a
F Sanfilippo1, C Corredor2, A Arcadipane1
1Department of Anaesthesia and Intensive Care, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Via Tricomi 5, 90127 Palermo, Italy.
Background:
Myocardial dysfunction may contribute to circulatory failure in sepsis. There is growing evidence of an association between left ventricular diastolic dysfunction (LVDD) and mortality in septic patients. Utilizing echocardiography, we know that tissue Doppler imaging (TDI) variables e' and E/e' are reliable predictors of LVDD and are useful measurements to estimate left ventricular (LV) filling pressures.
Methods:
We conducted a systematic review and meta-analysis to investigate the association of e' and E/e' with mortality of patients with severe sepsis or septic shock. In the primary analysis, we included studies providing transthoracic TDI data for e' and E/e' and their association with mortality. Subgroup analyses were conducted according to myocardial regional focus of TDI assessment (septal, lateral or averaged). Three secondary analyses were performed: one included data from a transoesophageal study, another excluded studies reporting data at a very early (<6 h) or late (>48 h) stage following diagnosis, and the third pooled data only from studies excluding patients with heart valve disease.
Results:
The primary analysis included 16 studies with 1507 patients with severe sepsis and/or septic shock. A significant association was found between mortality and both lower e' [standard mean difference (SMD) 0.33; 95% confidence interval (CI): 0.05, 0.62; P=0.02] and higher E/e' (SMD -0.33; 95% CI: -0.57, -0.10; P=0.006). In the subgroup analyses, only the lateral TDI values showed significant association with mortality (lower e' SMD 0.45; 95% CI: 0.11, 0.78; P=0.009; higher E/e' SMD -0.49; 95% CI: -0.76, -0.22; P=0.0003). The findings of the primary analysis were confirmed by all secondary analyses.
Conclusions:
There is a strong association between both lower e' and higher E/e' and mortality in septic patients.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
08:45Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025