Related Experiment Video
Updated: Feb 19, 2026

10:22
Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties Lactuca sativa L. and Crop Wild Relatives Lactuca spp.
Published on: June 30, 2020
14.4K
Simultaneous determination of rutin and ascorbic acid in a sequential injection lab-at-valve system
Mohammed Khair E A Al-Shwaiyat1, Yuliia V Miekh2, Tatyana A Denisenko2
1Department of Basic and Applied Science, Zarka University College, Al-Balqa Applied University, Al-Salt, 19117, Jordan.
Journal of Pharmaceutical and Biomedical Analysis
|November 10, 2017
Summary
A new sequential injection method enables simultaneous, sensitive determination of ascorbic acid (Asc) and rutin using 18-molybdo-2-phosphate Wells-Dawson heteropoly anion (18-MPA). This green, accurate lab-at-valve procedure offers precise results for Asc and rutin analysis.
Area of Science:
- Analytical Chemistry
- Chemical Analysis
- Spectrophotometry
Background:
- Ascorbic acid (Asc) and rutin are vital antioxidants with health benefits.
- Accurate simultaneous determination of Asc and rutin is crucial for quality control and research.
- Existing methods may lack sensitivity, simplicity, or environmental friendliness.
Purpose of the Study:
- To develop a green, simple, accurate, and highly sensitive lab-at-valve procedure for simultaneous Asc and rutin determination.
- To utilize the pH-dependent reaction kinetics of 18-molybdo-2-phosphate Wells-Dawson heteropoly anion (18-MPA) with reducing agents.
- To enhance analytical performance through external reaction chambers and segmented reaction mixtures.
Main Methods:
- Sequential injection lab-at-valve procedure.
- Utilized 18-molybdo-2-phosphate Wells-Dawson heteropoly anion (18-MPA) and its reaction rate dependence on pH.
- Employed external reaction chamber and segmented reaction mixture for improved precision and sensitivity.
- Measured absorbance at the isobestic point for linear calibration graphs.
Main Results:
- Simultaneous determination of Asc and rutin achieved with high sensitivity and accuracy (1-2%).
- Linear calibration curves obtained in concentration ranges of 0.3-24 mgL⁻¹ for rutin and 0.2-14 mgL⁻¹ for Asc.
- Low detection limits achieved: 0.13 mgL⁻¹ for rutin and 0.09 mgL⁻¹ for Asc.
- Successful determination of Asc and rutin in ascorutin tablets.
Conclusions:
- The developed sequential injection method is effective for simultaneous Asc and rutin quantification.
- The method offers a green, simple, accurate, and sensitive alternative for analyzing these compounds.
- It demonstrates applicability in pharmaceutical analysis, specifically for ascorutin tablets.

