Reduction of interferences in the analysis of Children's Dimetapp using ultraviolet spectroscopy data and target
Huggins Z Msimanga1, Truong Thach Ho Lam2, Nathaniel Latinwo1
1Department of Chemistry and Biochemistry, Kennesaw State University, Kennesaw 30144, Georgia, United States.
Abstract:
A calibration matrix has been developed and successfully applied to quantify actives in Children's Dimetapp®, a cough mixture whose active components suffer from heavy spectral interference. High-performance liquid chromatography/photodiode array instrument was used to identify the actives and any other UV-detectable excipients that might contribute to interferences. The instrument was also used to obtain reference data on the actives, instead of relying on the manufacturer's claims. Principal component analysis was used during the developmental stages of the calibration matrix to highlight any mismatch between the calibration and sample spectra, making certain that "apples" were not compared with "oranges". The prediction model was finally calculated using target factor analysis and partial least squares regression. In addition to the actives in Children's Dimetapp® (brompheniramine maleate, phenylephrine hydrogen chloride, and dextromethorphan hydrogen bromide), sodium benzoate was identified as the major and FD&C Blue #1, FD&C Red #40, and methyl anthranilate as minor spectral interferences. Model predictions were compared before and after the interferences were included into the calibration matrix. Before including interferences, the following results were obtained: brompheniramine maleate=481.3mgL-1±134% RE; phenylephrine hydrogen chloride=1041mgL-1±107% RE; dextromethorphan hydrogen bromide=1571mgL-1±107% RE, where % RE=percent relative error based on the reference HPLC data. After including interferences, the results were as follows: brompheniramine maleate=196.3mgL-1±4.4% RE; phenylephrine hydrogen chloride=501.3mgL-1±0.10% RE; dextromethorphan hydrogen bromide=998.7mgL-1±1.6% RE as detailed in Table 6.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:50Detection and Quantification of Plasmodium falciparum in Aqueous Red Blood Cells by Attenuated Total Reflection Infrared Spectroscopy and Multivariate Data Analysis
Published on: November 2, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference