The Jarvik 2000 left ventricular assist device as a bridge to transplantation: Japanese Registry for Mechanically
Hiroki Kohno1, Goro Matsumiya1, Yoshiki Sawa2
1Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.
Background:
The Jarvik 2000 ventricular assist device features a miniaturized intraventricular pump and an intermittent low-speed function that facilitates aortic valve opening. Despite its long history, little is known about the Jarvik device with regard to post-implantation outcomes.
Methods:
Prospectively collected data from 13 participating hospitals were extracted from the Japanese Registry for Mechanically Assisted Circulatory Support database to analyze mortality, morbidity and de-novo aortic regurgitation. Data on 83 patients who underwent implantation of the Jarvik 2000 were reviewed. Median support duration was 191 (maximum 758) days. All recipients underwent implantation as a bridge to transplantation.
Results:
Overall survival proportions at 1 and 2 years were 85.0% and 79.3%, respectively. Nine patients were in INTERMACS Level 1, and 28 patients were on mechanical circulatory support at the time of implantation. Causes of death included stroke, infection and device malfunction. Three patients had their device removed: 2 at the time of heart transplantation and 1 after recovery of the left ventricle. Common adverse events included major bleeding (27.7%), new infection (31.3%), stroke (20.5%) and device malfunction (20.5%). De-novo aortic regurgitation was observed in 17 patients, 6 of whom developed at least moderate regurgitation during follow-up.
Conclusions:
Mid-term survival after Jarvik 2000 implantation was satisfactory and comparable to that reported by other national and international registries (INTERMACS and IMACS) for continuous-flow LVADs. De novo aortic regurgitation occurred despite the intermittent low-speed effect of this device, with some recipients experiencing progressive worsening of aortic regurgitation within 2 years post-implantation.
Related Concept Videos
Continuous Renal Replacement Therapy
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tissue Transplantation
The Biology of Tissue Transplantation
The biology of tissue transplantation hinges on the Major Histocompatibility Complex (MHC) molecules. These molecules...
Kidney Transplant I: Introduction
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Kidney Transplant II: Surgical Procedure