Related Experiment Video
Updated: Feb 18, 2026

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Flap monitoring with continuous oxygen partial tension measurement in breast reconstructive surgery: A preliminary
Emilio Trignano1,2, Nefer Fallico3, Luca Fiorot1
1Department of Plastic and Reconstructive Surgery, University of Sassari, Sassari 07100, Italy.
Background:
The best method for the postoperative monitoring of flaps in reconstructive surgery is still a matter of debate. The aim of this study is to evaluate the usefulness of an oxygen partial tension monitoring system for the postoperative follow-up of a series of breast flaps, in addition to the traditional periodical clinical evaluations.
Patients And Methods:
Twenty-one consecutive female patients (mean age: 61 years) who underwent free- or pedicled-flap reconstruction of the breast were included in the study. Fifteen patients had a deep inferior epigastric perforator flap breast reconstruction, while the remaining six patients underwent a transverse rectus abdominus myocutaneous flap reconstruction. The Licox® Recon (Integra LifeSciences Corp, Plainsboro, New Jersey) system was used for the monitoring of the flaps. The oxygen partial tension (PtO2 ) values were displayed on the system monitor and registered with appropriate software for statistical analysis.
Results:
A decreasing trend in the mean PtO2 values was observed over the first five postoperative days. The mean values registered in the first postoperative day were higher than those observed in the subsequent four days. Three patients were lost due to misplacement of the probe. Among the remaining 18 flaps, 3 (17%) reported a remarkable decrease in PtO2 values, with the mean PtO2 registered in the second postoperative day being significantly lower than in the other flaps (7.3 ± 0.7 vs. 17.0 ± 0.9; P-value <.05). These three flaps have been promptly re-explored, with a final flap failure rate of 5.5% (1 flap).
Conclusions:
The continuous oxygen tension evaluation represents a promising method for the postoperative monitoring of breast reconstructive surgery flaps when used in combination with the traditional periodic clinical evaluations.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:05A Pre-clinical Rat Model for the Study of Ischemia-reperfusion Injury in Reconstructive Microsurgery
Published on: November 8, 2019
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...